Mercury Integration Capability Matrix

Jason Kaveney Updated by Jason Kaveney

Mercury Integration Capability Matrix

Credentials / Access Control

Features

Mercury

Brivo Panels

Cards / Fobs

YES

YES

PIN (4-8 digits)

YES

YES

Brivo Mobile Pass

Internet Only

YES

Brivo Wallet / NFC

NO

YES

Remote Unlock from Brivo Access

YES

YES

Two-factor Authentication

YES

YES

Lockdown from Brivo Access

YES

YES

Lockdown from Input Device

YES (Global) (New)

YES

Global Lockdown (Emergency Scenarios)

YES (New)

YES

Global Egress (Emergency Scenarios)

NO

YES

Brivo Access

Features

Mercury

Brivo Panels

Display Access Events for Event Tracker

YES

YES

Panel Connectivity Events

YES

YES

Real-time Device Status

YES

YES

Link Video Clips to Events

YES

YES

Door Configuration

Features

Mercury

Brivo Panels

Wiegand

YES

YES

OSDP V2

YES

YES

OSDP Multi-drop (2 readers per node)

YES

NO

Door Unlock Schedules

YES

YES

Door Ajar

YES

YES

Maximum Passthrough Period

255 seconds

600 seconds

REX/REX Unlock

YES

YES

In/Out Readers (Reporting)

YES

YES

Anti-passback

(Soft, Hard, and Door-based)

YES

YES

Debounce

NO

YES

Alarm Shunt

NO

YES

Invalid PIN Threshold/Shutdown

NO

YES

Two Factor Schedule/Interval

Schedule only

YES

Update Reader Firmware via OSDP

NO

YES

Update Reader Configuration via OSDP

NO

YES

Devices

Features

Mercury

Brivo Panels

Elevator

YES

YES

Monitored Devices

YES (New)

YES

Switch

YES

YES

Timer

YES

YES

Event Track

YES

YES

Valid Credential

YES

YES

Assa Abloy Aperio

NO

YES

Salto Sallis

NO

YES

Schlage AD-300

NO

YES

Schlage AD-400

NO

YES

Schlage NDE/NDEB

YES (New)

YES

Schlage LE/LEB

YES (New)

YES

Schlage PIM

Wiegand Only

YES

Schedules

Features

Mercury

Brivo Panels

Door Unlock

YES

YES

Two-factor Required

YES

YES

Card Required

YES

YES

Holidays

YES

YES

Schedule Exceptions

YES

YES

Door Override

NO

YES

Group Enabled Schedules

NO

YES

Credentials

Features

Mercury

Brivo Panels

30-bit Wiegand

NO

YES

32-bit CSN

YES

YES

Allegion 34-bit Wiegand

NO

YES

Allegion 40-bit

NO

YES

Casi-Rusco 40-bit

NO

YES

Generic 36-bit with Vendor Code

NO

YES

HID 33-bit

NO

YES

HID 33-bit D10202

NO

YES

HID 37-bit

YES

YES

HID 37-bit with Facility Code

YES

YES

HID Corporate 1000 (35-bit)

YES

YES

HID Corporate 1000 48-bit

YES

YES

PIV-I

NO

YES

Standard 26-bit

YES

YES

Wavelynx 56-bit (LEAF)

YES (New)

YES

Notifications

Features

Mercury

Brivo Panels

Door Ajar / Closed

YES

YES

Door Forced Open

YES

YES

Intrusion Alarm / Cleared

NO

YES

Too many invalid PINs

NO

YES

Unlock schedule restored/door locks by keypad

NO

YES

Door Unlocked by Time

YES

YES

Failed Access by Unknown Person

YES

YES

Failed Access by Known User

YES

YES

Low Battery

NO

YES

Device Engaged / Disengaged

YES

YES

Unit Opened / Closed

NO

YES

AC Power Loss / Restored

YES

YES

Control Panel Communication Failure

YES

YES

Schedules

Features

Mercury

Brivo Panels

Door Unlock

YES

YES

Two-factor Required

YES

YES

Card Required

YES

YES

Holidays

YES

YES

Schedule Exceptions

YES

YES

Door Override

NO

YES

Miscellaneous

Features

Mercury

Brivo Panels

Remote Firmware Upgrade

YES

YES

Remote Support by Brivo CSRs

YES

YES

LifeSafety Power Enclosures

YES

YES

ALTRONIX Trove Enclosures

YES

YES

How did we do?

Configuring Multiple OSDP Readers per Node

Setting up Multi-Drop for Multiple OSDP Readers per Door

Contact