Brivo Access Firmware Release Notes

Larry Wile Updated by Larry Wile

Brivo Access Firmware Release Notes

Brivo Firmware Release 6.2.4.2

11/17/2023

This version of firmware is for use with ACS6000/6100, ACS300, ACS100, and ACS-SDC-E control panels only.

New Features
Details
-Panels now send notifications to Brivo Door Stations to update individual Faceprints.

-The Brivo Door Station default production URLs for video have been streamlined.
Fixes
Details
-Fixed an issue which now allows for the smooth firmware upgrade of ACS6100 boards.

Brivo Firmware Release 6.2.4.1

10/30/2023

This version of firmware is for use with ACS6000/6100, ACS300, ACS100, and ACS-SDC-E control panels only.

New Features
Details
-Brivo now supports the Brivo Door Station.

-WebCLI includes Brivo Door Station Device information in the hardware/firmware upgrade page.

-Brivo Door Station uses the panel log period.

-Increase V2 board temperature settings to support operating requirements.

-Security updates and patching.
Fixes
Details
-Fixed an issue where the ACS6100 was not properly working with the Brivo Door Station.

-Fixed an issue where the ACS-SDC was not properly displaying Brivo Door Station details.

-Fixed an issue where the ACS300 panel dump was not displaying the proper states of switches.

-Fixed an issue where there were communication delays between Brivo Door Station and the control panel.

Brivo Firmware Release 6.2.4

08/31/2023

This version of firmware is for use with ACS6000/6100, ACS300, ACS100, and ACS-SDC-E control panels only.

New Features
Details
-Production support for the V2 versions of the ACS300 and ACS6000 mainboards.

-Improvements to Brivo Door Station operations.

-Updates to support new Egress / Ingress capabilities.

-OSDP improvements and updates.

-Translation updates and the Swedish language is now available.

-Security updates and patching.
Fixes
Details
-Fixed an issue where the ACS100 internal reader tamper control was not following defined settings.

-ACS-SDC should now display OSDP reader information correctly in the WebCLI.

-Bot Detection improvements to reduce false positives.

-Fixed an issue where not all control panels were properly displaying their current state in the WebCLI.

-Fixed an issue where panels were not recognizing empty credentials as valid data.

Brivo Firmware Release 6.2.3.2

05/12/2023

This version of firmware is for use with ACS6000/6100, ACS300, ACS100, and ACS-SDC-E control panels only.

New Features
Details
-Monitored devices support configuring the firing outputs when receiving either Device Engaged or Device Ajar messages.
Fixes
Details
-The panel now treats empty credential fields as valid data.

Brivo Firmware Release 6.2.3

03/06/2023

This version of firmware is for use with ACS6000/6100, ACS300, ACS100, and ACS-SDC-E control panels only.

New Features
Details
-SDC units now report tamper status/events back to Brivo servers.

-SDC units now support antipassback.

-SDC WebCLI interface now displays warning message if using default username and password.
Fixes
Details
-Fixed an issue so that panels no longer display incorrect warning or log messages.

-Fixed an issue so that both OSDP readers on an ACS6000-MB now follow LED color logic properly.

-Fixed an issue where bot detection was triggering false alarms.

-Fixed an issue so that third party OSDP readers now function properly when connected to an ACS6100 door board.

-Corrected some grammatical errors in WebCLI.

Brivo Firmware Release 6.2.2.1

01/30/2023

This version of firmware is for use with ACS6000/6100, ACS300, ACS100, and ACS-SDC-E control panels only.

New Features
Details
-Installers can now select EU Data Region in the WebCLI.

-Updates for new ACS6000/ACS300 panels to allow more reliable ADMIN port operation.
Fixes
Details
-Fixed an issue where NFC Credentials were having leading 0's trimmed leading to credentials not matching.

Brivo Firmware Release 6.2.2

12/05/2022

This version of firmware is for use with ACS6000/6100, ACS300, and ACS100 control panels only.

New Features
Details
-Salto locks now support office & apartment mode.

-Assa Abloy locks now support office & apartment mode.

-The WebCLI panel interface now supports I/O testing.
Fixes
Details
-Fixed an issue where the panel did not properly connect to multiple Aperio hubs simultaneously.

-Fixed an issue where the panel would not reload database after changing operation mode.

-Fixed an issue where door position input and REX input occurring simultaneously caused a false door forced event.

Brivo Firmware Release 6.2.0.1

10/26/2022

This version of firmware is for use with ACS6000/6100, ACS300, and ACS100 control panels only.

Fixes
Details
-Fixed an issue where User was unable to set a static IP on an ACS300 after updating the firmware to 6.2.0.

Brivo Firmware Release 6.2.0

09/06/2022

This version of firmware is for use with ACS6000/6100, ACS300, and ACS100 control panels only.

New Features
Details
-ACS100 now provides support for Brivo Smart Reader LED colors based on lock and alarm states.

-Improved security checks for new NFC credentials.

-Assa Abloy tamper events will now display in the real time log when sent to Brivo servers.

-Brivo control panels now support 802.1x Radius Server LAN security protocols.

-Panel data validation function can now detect users associated with more than 16 groups and preserve prior configuration if errors are detected.

-Users now have the ability to set entire IP range and subnet mask for Admin port (only for ACS6000 and ACS300 panels).

-Several optional features added that meet New York Privacy Law requirements.

-Updated OpenSSL to version 3.0.3

-Updated self-signed certificates to meet new browser requirements. Users will be presented the click to proceed option in Chrome.
Fixes
Details
-Fixed an issue where User related events from Assa Abloy and Salto locks would not be sent to Brivo servers when the “no tracking user“ condition was met.

-Fixed an issue where users could not log into the ACS100 WebCLI when there was more than one ACS100 the local network.

-Fixed an issue where the panel daemon restarted after using a BLE credential.

-Fixed an issue that prevented certain network configuration changes when the LAN interface on panels was set to DHCP and the panel had not yet obtained an IP address.
Brivo Firmware Release 6.1.9.1

05/27/2022

This version of firmware is for use with ACS6000/6100, ACS300, and ACS100 control panels only.

New Features
Details
-WebCLI now available in German.

-Updates made to Dutch, French, and Spanish versions of the WebCLI.

-This release adds the ability to maintain critical system information after auto-recovery mechanisms are triggered.

-This release allows ACS6100 controller boards to request hardware revision numbers from door and I/O boards through the CAN bus.
Fixes
Details
-Fixed an issue where events were not posting properly based on end-of-line settings.

-Fixed an issue where panel was improperly triggering antipassback states for unconfigured groups.

-Fixed a hardware issue where firmware updates were failing due to default internal clocking source.

How did we do?